Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Famco Chimney Cap Installation: The Kennesaw Owner’s Guide
Famco chimney cap installation in Kennesaw typically runs $340-$620 for most single-flue residential setups, including the cap, collar fit, sealant, and labor. We stock Famco-compatible caps in 8″, 10″, 12″, and 13″ round flue sizes on our Kennesaw trucks, and most installs are completed in under two hours once on site. Most homeowners discover their Famco cap has failed after a storm blows through Kennesaw - you’ll find pieces in the yard, or water starts showing up on the smoke chamber walls during your annual sweep.
Which Famco Models This Applies To
Famco caps break down into two main series you’ll see around Kennesaw: the standard galvanized line and the stainless multi-flue assemblies. The galvanized units carry a model stamp on the underside of the lid - look for “FAMCO” followed by a dash and the diameter (FAMCO-10 for 10-inch, for example). Multi-flue models have a riveted spec plate on the front skirt showing width, depth, and mesh size.
Here’s where owners get tripped up: Famco changed their base flange design around 2016. The older caps used a three-screw collar; post-2016 units switched to a four-point clamp system. If you’re matching to an existing collar, that year matters. We carry both mounting styles through our Haven buying network, sourced alongside DuraFlex, HeatShield, and Gelco materials to keep pricing honest.
OEM Famco caps run 15-20% more than quality aftermarket equivalents we spec from the same suppliers. For most Kennesaw homes, the aftermarket unit matches the stainless grade (304 or 316, depending on exposure) and carries the same 10-year warranty against rust-through. We write down both options with the part number and source before you decide anything.
Signs Your Famco Chimney Cap Is Failing

- Lid separation or blow-off. The stamped steel lid on galvanized Famco caps fatigues at the bend points after 7-10 years in Georgia’s UV and thermal cycling. Once the seam cracks, the next thunderstorm lifts it like a wing. We find these in Kennesaw yards after every March wind event.
- Mesh screen pulling away from the frame. The spot-welds holding the spark-arrestor mesh corrode from the inside out, especially if you’re burning pine or unseasoned oak common in Cobb County. Gaps larger than a quarter-inch let embers through and void your homeowner’s fire clause with most carriers.
- Visible rust streaking down the flue tile. Surface rust on galvanized steel is normal; orange runoff that stains the crown means the cap’s protective layer has failed. In Kennesaw’s humidity, that accelerates once it starts - we’ve pulled caps where the metal was paper-thin after just two seasons of active bleeding.
- Water in the firebox after rain. A cap that sits crooked, has a dented lid, or lost its storm collar seal lets water track down the flue. The tell is a damp ash smell or actual puddling on the hearth. Left alone, it degrades the smoke chamber and damper - repairs that run well past the cost of a cap swap.
- Animal intrusion. Squirrels and chimney swifts push through weakened mesh or lift a loose lid. If you’re hearing scratching or finding nesting debris, the cap’s structural integrity is already compromised. Kennesaw’s tree canopy along streets near Kennesaw Mountain National Battlefield Park makes this a recurring late-winter call for us.
Before
AfterReplacement Cost & What’s Included
| Component | Typical Range (Kennesaw) |
|---|---|
| Single-flue Famco-compatible cap (galvanized) | $180-$260 |
| Single-flue Famco-compatible cap (304 stainless) | $240-$340 |
| Multi-flue custom fit (stainless) | $380-$520 |
| Labor, sealant, collar adjustment | $160-$200 |
| Total installed | $340-$620 |
What drives the range: flue diameter, whether the existing collar can be reused, and access height. A walkable roof in Kennesaw’s Legacy Park neighborhood runs at the lower end; a two-story colonial off Stilesboro Road with a steep pitch adds ladder time and safety rigging. We deliver a written price before work starts - Haven Standard Clause 1 - with the cap spec, labor line, and warranty terms itemized. Every install includes a photo record of the finished mount and seal, archived under Clause 4 of the Haven Standard. The 365-Day Done Right Promise covers workmanship; manufacturer defect coverage runs 10 years on stainless units.
DIY or Call Us?

You can safely check three things from the ground: whether the lid is seated square, whether mesh gaps are visible, and whether rust streaks show on the exterior flue tile. Use binoculars - don’t climb.
We don’t recommend homeowner installation. Chimney cap work requires ladder positioning on pitched surfaces, working at height with both hands free, and proper sealant application that won’t void the warranty. More critically, a poorly seated cap traps exhaust gases or creates a downdraft condition that pushes carbon monoxide into the living space. In Kennesaw’s older homes with original clay flue liners, the collar fit is fussy - too tight and you crack the tile; too loose and you have a new water problem by October.
Our crew carries the full Famco-compatible size range, the right sealants for Georgia’s freeze-thaw, and the camera to document the flue condition before we mount anything. Call (678) 535-2204 - we answer live, and Corrine Halstead or a named technician will text when we’re en route.
FAQs
Galvanized Famco caps average 8-12 years in Georgia’s climate before significant rust appears; 304 stainless units routinely go 15-20 years. Proximity to Kennesaw Mountain’s higher wind exposure can shorten that by a season or two. Call (678) 535-2204 and we’ll assess what’s on your flue - estimates are free.
Mesh re-welding and lid re-seaming are possible but rarely cost-effective; the labor runs nearly as much as a new cap with a shorter effective lifespan. We write it down before we ask you to decide anything - bring us a photo and we’ll give you both numbers. Call (678) 535-2204.
Most Famco cap replacements take 45 minutes to 90 minutes on site, including old cap removal, collar inspection, new unit fit and seal, and photo documentation. Multi-flue or custom-width jobs run closer to two hours. Call (678) 535-2204 to book - we stock the common sizes in Kennesaw.
We stock Famco-compatible caps in 8″, 10″, 12″, and 13″ round, plus adjustable multi-flue frames, on our Kennesaw trucks. Less common sizes (oval, large rectangle) source within 48 hours through our Haven buying network alongside DuraFlex, HeatShield, and Gelco materials. Call (678) 535-2204 - if we don’t have it today, we’ll tell you exactly when we will.
Level Two Chimney Kennesaw is an independent service provider and is not affiliated with Famco Manufacturing. We source Famco-compatible and equivalent-grade caps through our Haven Standard buying network.
Written by Corrine Halstead, Owner, Level Two Chimney Kennesaw at Level Two Chimney Kennesaw, serving Kennesaw and nearby areas.





Before
After
Before
After
Before
After